Part Number Hot Search : 
XFATM 1H222 LT1171CQ 30006 K2499 P2022 2SB1589 RWP0304
Product Description
Full Text Search
 

To Download NLP40 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 NLP40 Series
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES * * * * * * * *
Single, dual and triple output
40-50 W AC/DC Universal Input Switch Mode Power Supplies 1 4.25 x 2.5 x 1.15 inch package (1U applications) Smallest industry package Overvoltage and short circuit protection 40 W with free air convection EN55022, EN55011 conducted emission level B EN61000-4-2, -3, -4, -5, -6 immunity compliant UL, VDE and CSA safety approvals Available RoHS compliant
The NLP40 series is a 40 W universal input ac-dc power supply on a 4.25 x 2.5 inch card with a maximum component height of 1.15 inches for use in 1U applications. This product is the smallest standard 40 W package in the industry making the series ideal for communication applications with space constraints where a standard 5 x 3 inch card solution is not suitable. The NLP40 provides 40 W of output power with free air convection cooling which can be boosted to 50 W with 20 CFM of air. Standard features include overvoltage and short circuit protection. The series, with full international safety approval and the CE mark, meets conducted noise EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data networking, computer and telecom applications such as hubs, routers, POS terminals, LCD projectors, cable modems and PABX's. This list is not exclusive as the generic feature set of the NLP40 series with industry standard output configurations provides a solution for most low power applications including many industrial applications.
All specifications are typical at nominal input, full load at 25 C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS Total regulation (Line and load) Rise time Transient response Temperature coefficient Overvoltage protection Short circuit protection Minimum output current INPUT SPECIFICATIONS Input voltage range (See Note 9) Input frequency range Input surge current Safety ground leakage current Input current Input fuse 120 Vac, cold start 230 Vac, cold start 120 Vac, 60 Hz 230 Vac, 50 Hz 120 Vac 230 Vac UL/IEC127
(10)
GENERAL SPECIFICATIONS 2.0% 5.0% 1.0 s, max. Hold-up time Efficiency Isolation voltage Switching frequency Approvals and standards (See Note 8) Weight MTBF MIL-HDBK-217F Input/output Input/chassis Fixed 120 Vac 230 Vac 12 ms @ 40 W 20 ms @ 40 W 75% typical 3000 Vac 1500 Vac 65 kHz, 5 kHz EN60950, IEC950, UL1950 VDE0805, CSA C22.2 No. 950 200 g (7.06 oz) 150,000 hours min.
Main output Auxiliary outputs At turn-on
Main output 5.0% max. dev., 25% step at 0.1 A/s 1 ms rec. to 1.0% 0.02%/C Main outputs Cyclic operation Single Multiple 135%, 15% Continuous 0A (See Note 5)
ENVIRONMENTAL SPECIFICATIONS Universal input 90-264 Vac 120-370 Vdc 47-440 Hz 15 A max. 30 A max. 0.2 mA 0.4 mA 1.4 A rms 0.7 A rms 250 Vac H 3.15 A Thermal performance (See Notes 6, 7, 9) Operating ambient, 0 C to +70 C (see derating curve) Non-operating -40 C to +70 C 50 C to 70 C ambient, Derate to convection cooled 50% load 0 C to 50 C, ambient, 40 W convection cooled 0 C to 50 C ambient, 50 W 20 CFM forced air Peak (0 C to +50 C, 60 s) (See Note 2) Non-condensing Operating Non-operating 5-500 Hz per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4 G rms peak 516.4 Part IV
Relative humidity Altitude Vibration (See Note 4) Shock
EMC CHARACTERISTICS Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity
EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 3 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3
Perf. Perf. Perf. Perf. Perf. Perf.
level B level A criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 criteria 1
File Name: NLP40.pdf Rev (03): 08 Nov 2005
NLP40 Series
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
OUTPUT VOLTAGE +3.3 V (IA) +12 V (IB) -12 V (IC) +5 V (IA) +12 V (IB) -12 V (IC) +5 V (IA) +15 V (IB) -15 V (IC) +12 V (IA) -12 V (IB) +5 V (IA) +12 V (IB) 3.3 V (IA) 5V 12 V 15 V 24 V 48 V Notes
1
Single, dual and triple output
40-50 W AC/DC Universal Input Switch Mode Power Supplies 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT RIPPLE MAX 4A 2A 0.2 A 4A 2A 0.2 A 4A 1.6 A 0.2 A 1.8 A 1.8 A 4A 2A 8A 8A 3.3 A 2.6 A 1.6 A 0.8 A
(1) (3)
TOTAL REGULATION
MODEL NUMBER NLP40-76T366J
(11,12)
PEAK 5A 3A 1A 5A 3A 1A 5A 2A 1A
(2)
FAN
(1)
4.5 A 3A 0.5 A 4.5 A 3A 0.5 A 4.5 A 2A 0.5 A 2.1 A 2.1 A 4.5 A 3A 9A 9A 4A 3.3 A 2A 1A
50 mV 120 mV 120 mV 50 mV 120 mV 120 mV 50 mV 150 mV 150 mV 120 mV 120 mV 50 mV 120 mV 50 mV 50 mV 120 mV 150 mV 240 mV 300 mV
2.0% 5.0% 5.0% 2.0% 5.0% 5.0% 2.0% 5.0% 5.0% 2.0% 5.0% 2.0% 5.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0%
(5)
NLP40-7608J
(5)
NLP40-7610J
(5)
2.2 A 2.2 A 5A 3A 10 A 10 A 4.5 A 3.6 A 2.5 A 1.1 A
NLP40-7627J
(5)
NLP40-7629J
(5)
NLP40-76S3J NLP40-7605J NLP40-7612J NLP40-7615J NLP40-7624J NLP40-7617J
Maximum output power is 40 W for natural convection cooling. With 20 CFM fan cooling, the maximum output power is 50 W. 2 Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total reg. limits. 3 Figure is peak-to-peak. Output noise measurements are made across a 50 MHz bandwidth using a 12 inch twisted pair, terminated with a 47 F capacitor. 4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5 Hz to 500 Hz. 5 For multiple output units (except -7627J, 76T366J) to maintain stated regulation then: 0.25 IA / IB 5, for IB > 0.3 A 0.50 IA / IB 5, for IB < 0.3 A For maximum output current I(C) on triple output models, i.e. for IC = IMax., I A min. 0.5 A and IA IB. For NLP40-7627J only, to maintain stated regulation then: 0.5 IA / IB 2. For NLP40-76T366J only, to maintain stated regulation then: 0.25 IA / IB 4. 6 For optimum reliability, no part of the heatsink should exceed 120 C, and no semiconductor case temperature should exceed 130 C. 7 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. 8 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 9 When the input voltage is <90 Vac the operating range is 0 C to +40 C. 10 For system EMI compliance, a ground choke may be required before connecting the ground wire to the chassis. It is recommended that this ground choke be placed as close as possible to the systems ac inlet to eliminate noise pick-up in the system. 11 The `J' suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 12 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative.
DERATING CURVE Output Power (Watts)
50W 20 CFM FORCED AIR COOLING 40W
NATURAL CONVECTION COOLING
25W 20W
0C
10C
20C
30C
40C
50C
60C
70C
File Name: NLP40.pdf Rev (03): 08 Nov 2005
NLP40 Series
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
Single, dual and triple output
40-50 W AC/DC Universal Input Switch Mode Power Supplies 3 For the most current data and application support visit www.artesyn.com/powergroup/products.htm
4.25 (107.95) 4.00 (101.60) J1 N L 2.50 (63.50) P1 T1 C5 2.25 (57.15) F1 1 0.125 (3.175)
J2
ALL DIMENSIONS IN INCHES (mm)
MAXIMUM COMPONENT HEIGHT 1.15 (29.21) TOLERANCE: .xxx 0.005" .xx 0.02"
Mounting Hole Diameter 0.138 (3.50) Typical
Input and output connectors
AC (J1) connector type Molex 26-60-4030 type. DC (J2) connector type Molex 26-60-4060 type.
INPUT PIN CONNECTIONS J1 Pin 1 AC Line No Pin AC Neutral P1 Pin 1 Safety Ground
Mating connectors
AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J2) mating connector type Molex 09-50-3061 with Triurcon 6838 or equivalent crimp terminals. Note: The input and output connectors are the same as those used on NFS40, NFN40, NAL40 and NAN40.
Pin 2 Pin 3
J2 Pin 1 Pin 2 International Safety Standard Approvals
VDE0805/EN60950/IEC950 File 10401-3336-0093 Licence No. 93662 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C
OUTPUT PIN CONNECTIONS SINGLE DUAL TRIPLE +Vout +Vout +Vout Return Return Return V (B) V (A) V (A) Return Return Return V (B) V (A) V (A) Return Return V (C)
Pin 3 Pin 4 Pin 5 Pin 6
Datasheet (c) Artesyn Technologies(R) 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: NLP40.pdf Rev (03): 08 Nov 2005


▲Up To Search▲   

 
Price & Availability of NLP40

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .